EXPERT System Variable
EXPERT System Variable
GstarCAD 2022 → System Variables → E
Function Description:
The EXPERT system variable is used to control whether certain prompts are issued.
| Type | Integer |
| Saved in | Not saved |
| Initial value | 0 |
| Range | 0,1,2,3,4,5 |
System Variable Value:
0: display all prompts
1: display all prompts
2: forbid to display prompts above and "Block already defined. Redefine it?" or "A drawing with this name already exists. Overwrite it?"
3: do not display prompts above, and prompts by LINETYPE command, if users try to load loaded linetype or create new line type in a drawing which has defined linetype
4: do not display prompts above, and prompts for "Save" option when the entered name already exists by UCS command and VPORTS command
5: forbid to display the prompts by -DIMSTYLE :"That name is already in Use, redefine it?" . Do not display the same prompts by -SCALELISTEDIT
Other versions with matching text