SETBYLAYERMODE system variable


Function Description:

The SETBYLAYERMODE system variable is used to control which property are selected for SETBLAYER command.

Type : Integer
Saved in : Registry
Initial value : 255
Range : 0,1,2,4,8,16,32,64,128

The setting is stored as a bitcode using the sum of listed system variable values.

System Variable Value:

0 : none
1 : color property
2 : linetype property
4 : lineweight property
8 : material property
16 : plot style property
32 :plot style property
64 :change "ByBlock" to be "Bylayer" including blocks
128 :change "ByBlock" to be "Bylayer" including blocks

 



Article ID: 1809
Created: July 26, 2021
Last Updated: July 26, 2021
Author: GstarCAD MY /KW

Online URL: https://kb.gstarcad.com.my/article/setbylayermode-system-variable-1809.html