DYNMODE System Variable — GstarCAD 2027
DYNMODE System Variable
GstarCAD 2027 · Command Reference
Function Description:
The DYNMODE system variable is used to turn on or off the dynamic input mode.
| Type | Integer |
| Saved in | Registry |
| Initial value | 3 |
| Range | 0,1,2,3 |
If specifying a negative value to DYNMODE system variable, it turns off the dynamic input but stores its settings.
System Variable Value:
0: turn off all dynamic input including dynamic prompts
1: pointer input on
2: dimensional input on
3: both pointer input and dimensional input on
If specified DYNPROMPT to be 1, it displays dynamic prompts when setting DYNMODE to be 1,2, or 3.
If specified DYNMODE to be 2 or 3, it switches to pointer input when inputting comma, angle bracket (>) or selecting multiple grips.
If specified DYNMODE to be 1,2, or 3, it temporarily closes all functions instead of F12.
Users can set dynamic input option in drafting settings dialog box.