DIMLUNIT System Variable — GstarCAD 2027
DIMLUNIT System Variable
GstarCAD 2027 · System Variables
System Variables > D System Variables > DIMLUNIT
Function Description:
The DIMLUNIT system variable is used to set units for all dimension types(except angular dimension).
| Type | Integer |
| Saved in | Drawing |
| Initial value | 2 |
| Range | 1,2,3,4,5,6 |
System Variable Value:
1: scientific
2: decimal
3: engineering
4: architecture (always stacked displaying)
5: fractional (always stacked displaying)
6: Microsoft Windows Desktop (decimal format using Control Panel settings for decimal separator and number grouping symbols)
Other versions with matching text
2016 · 2017 · 2018 · 2019 · 2020 · 2021 · 2022 · 2023 · 2024 · 2025 · 2026