# LOFTNORMALS System Variable
[GstarCAD 2026](Help%20System/GSTARCAD/2026/Index.md) → [System Variables](Help%20System/GSTARCAD/2026/System%20Variables/(System%20Variables).md)
**Function Description:**
The LOFTNORMALS system variable is used to control the normals of a lofted object when it passes through cross sections.
| | |
| --- | --- |
| Type | Integer |
| Saved in | Drawing |
| Initial value | 6 |
| Range | 0 ~ 6 |
If specified paths or guide curves, this system variable is ignored.
**System Variable Value:**
**0:** ruled
**1:** smooth fit
**2:** start cross section
**3:** end cross section
**4:** start and end cross sections
**5:** all cross sections
**6:** use draft angle and magnitude
---