# DYNMODE System Variable [GstarCAD 2016](../../Index.md) → [System Variables](../%28System%20Variables%29.md) → [D](%28D%29.md) ## Function Description: The DYNMODE system variable is used to turn on or off the dynamic input mode. | | | | --- | --- | | Type | Integer | | Saved in | Registry | | Initial value | 3 | | Range | 0,1,2,3 | If specifying a negative value to DYNMODE system variable, it turns off the dynamic input but stores its settings. ## System Variable Value: **0:** turn off all dynamic input including dynamic prompts **1:** pointer input on **2:** dimensional input on **3:** both pointer input and dimensional input on If specified DYNPROMPT to be 1, it displays dynamic prompts when setting DYNMODE to be 1,2, or 3\. If specified DYNMODE to be 2 or 3, it switches to pointer input when inputting comma, angle bracket (\>) or selecting multiple grips. If specified DYNMODE to be 1,2, or 3, it temporarily closes all functions instead of F12. Users could set dynamic input option in drafting settings dialog box. --- ## Other versions with matching text [GstarCAD 2017](../../../2017/System%20Variables/D/DYNMODE%20System%20Variable.md) · [GstarCAD 2018](../../../2018/System%20Variables/D/DYNMODE%20System%20Variable.md) · [GstarCAD 2019](../../../2019/System%20Variables/D/DYNMODE%20System%20Variable.md) · [GstarCAD 2020](../../../2020/System%20Variables/D/DYNMODE%20System%20Variable.md) · [GstarCAD 2021](../../../2021/System%20Variables/D/DYNMODE%20System%20Variable.md)